Every process has some degree of variability. However, high quality medical device contract manufacturers have experience in managing that variability through process controls, packaging choices, and effective measurement tools.
In this article, we will delve into the essential elements of medical device packaging validation and highlight the key capabilities that a contract manufacturer should have in order to effectively verify that the final, assembled, packaged and sterilized device is effectively protected throughout the entire production process for eventual delivery to the end patient.
Let’s start with what needs to be measured and how the standards are established…
The ISO 11607 standard sets the requirements for packaging for terminally sterilized medical devices. These requirements establish the industry standards that medical device contract packaging companies must follow to design the appropriate packaging and the accepted validation methodologies. Per the ISO standard, the testing governs “materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility for terminally sterilized medical devices until the point of use”.
All of the elements that we will discuss in this article come back to the testing requirements established in the ISO 11607 guidelines.
Once the sealing equipment is qualified and validated for use, packaging validation begins with establishing optimal sealing parameters. Based on their own experience and input from the customer, the contract manufacturer develops a process to establish a measurement baseline against which all future testing can be measured. This is an important step to identify and control materials and processing variables that may impact the production process and cause the packaged device to fall outside the performance standards established.
Experienced medical device contract manufacturers typically have a rigorous Design of Experiments methodology to study and measure the relationship between various input factors that may affect the process and track the impact on the final assembled and packaged device.
Real-Time and Accelerated Aging studies are conducted to verify that the packaging will remain stable throughout the established shelf life of the device. Due to time-constraints, accelerated aging may be done in conjunction with real-time aging to enable the device to be cleared for launch more quickly. This does not mean that any safety or quality standards are relaxed; rather it points to the importance of experience in identifying the appropriate temperature, humidity and storage conditions that the product will likely be subjected to. These conditions will be used to set the aging conditions and to determine how effectively the packaging withstands those environments. All of these are designed to ensure that the packaging maintains its integrity and continues to protect the medical device for its full, intended shelf-life.
Another important validation test is to determine how well the packaged device will manage the distribution process. During the course of the process, the packaged device has to travel from a production facility to a warehouse to the sterilizer (and back), and finally to be shipped to the end customer. Each step has an impact on the integrity of the package and the device inside. It is vital to establish process control around typical distribution conditions and to determine the acceptable minimum and maximum range of variability. In this way, the contract manufacturer can track any variances that might impact the integrity of the product and packaging and can use this to quickly isolate key factors that may need to be modified. Effectively managing the process and testing comes with years of experience and knowing what to plan for.
To conduct the necessary validation studies, it is a real advantage to work with a contract manufacturing company that has an ISO 17025 accredited lab on-site. It is a signal that they have experienced engineers, microbiologists and lab technicians that understand validation testing. Additionally, it is a good indication that they value testing and have made the investment to build a high-quality laboratory.
Some of the tests used to validate the integrity of the packaging include:
All in all, it is a very complex undertaking and not one you should take lightly. That is why many OEMs choose to outsource packaging and assembly completely to an experienced contract manufacturer.
We use essential cookies to keep this website working. Optional cookies are off unless you accept them. Choose Accept all, Reject optional, or Cookie settings. You can change your choice at any time. Cookie Policy
Manage your cookie preferences below:
Essential cookies enable basic functions and are necessary for the proper function of the website.
Marketing cookies are used to follow visitors to websites. The intention is to show ads that are relevant and engaging to the individual user.
Interactive office maps connect your browser to Google and share information such as your IP address. Office addresses remain available when maps are disabled.
Service URL: policies.google.com (opens in a new window)
You can find more information in our Pro-Tech Design & Manufacturing Cookie Policy and Pro-Tech Design & Manufacturing Privacy Policy.